Description
The Fluke Norma 6000 Series Portable Wideband Precision Power Analyzers give you more freedom than ever before to make high accuracy power measurements wherever you need to—whether in the lab, or in the field. Designed for portability the lightweight, battery powered Fluke 6000 Series eliminates the need to carry large, fragile, expensive analyzers into the field, allowing you to make measurements directly at the load in nearly any environment. By measuring directly at the load, you can discover how the equipment operates under real-world conditions, with real-world variables, not just at a test bench or in the lab.
Key features
- Measure voltage, current, active power, reactive power, apparent power, power factor and harmonics with associated values
- Get accurate, precise results with 0.1% measurement accuracy and a 500kHz bandwidth
- Take precision power measurements almost anywhere – highly portable, battery powered analyzer weighing only 3.5kg with up to 10 hours of battery life.
Inputs | Norma 6003 | 3 Voltage + 3 Current |
Norma 6003+ | 3 Voltage + 3 Current + 1 Motor | |
Norma 6004 | 4 Voltage + 4 Current | |
Norma 6004+ | 4 Voltage + 4 Current + 1 Motor | |
Sample rate | 200ks/s | |
Measurement update rate | 100ms, 200ms, 500ms, 1s | |
Dimensions (H * W * L) | 298mm x 215m x 96mm | |
Weight | 3.5 kg (7.7 lbs) | |
Display | 5.7 inch, TFT LCD, 640×480 | |
Operating temperature | -10 °C to +50 °C | |
Storage temperature | -30 °C to +60 °C | |
Operating humidity | Non-condensing (< 10 °C ) ≤ 90 % RH (at 10 °C to 30 °C) ≤ 75 % RH (at 30 °C to 40 °C) ≤ 45 % RH (at 40 °C to 50 °C) |
|
Operating altitude | 2000m | |
Storage altitude | 12000m | |
Ingress protection | IP 50 (Terminals mated) according to IEC 60529: | |
Battery | BP 291, 10.8V/5000mAh, 54Wh IEC 62133, UN38.3 Operating time: 10 Hours (on battery) |
|
Safety | IEC 61010-1: Pollution Degree 2 IEC 61010-2-030: CAT IV 600V, CAT III 1000 V |
|
EMC | IEC 61326-1: Industrial IEC 61326-2-2 |
|
Warranty | 1 Year | |
Communication Interface | USB/RS485 | |
Dual Analyzer Synchronization Mode | Able to extend to 6, 7 or 8 channels (using multiple instruments) | |
PC Software | Fluke Power Analyzer software | |
Storage Capacity | 32GB | |
Data trend storage rate | As per display rate | |
Main Function | Meter, Scope, Harmonic, Phasor, Trend | |
Measuring Parameters | RMS, DC Component, AC Component, Rectified Mean, Peak Value, Peak-Peak, Crest Factor, Form Factor, Fundamental Component, Fundamental Content, Harmonic Distortion, Harmonic Content, Harmonic Factor for voltages and currents, Active Power, Reactive Power, Apparent Power, Power Factor, Phase Shift, Efficiency, Impedance, Electric Energy, Charge/Discharge capacity (Ah), Frequency, Motor Speed, Torque, Mechanical Power, Mechanical Energy, Summation function |
Electrical Specifications | |
Voltage | |
Range | 10 V, 100 V, 1000 V |
Crest Factor | CF ≤ 2 |
Maximum Voltage | 10 % overload |
Input Impedance | 2M Ω/10pF (Typical) |
Temperature Coefficient | 0.05 * (Spec)/k |
Bandwidth | 1000V range: 500kHz; 100V range: 200 kHz; 10V range:100 kHz |
CMRR | 120 dB @ 50/60 Hz |
Accuracy (% reading + % range) | |||
Range | 1000 V | 100 V | 10 V |
DC | 0.1 + 0.1 | 0.1 + 0.1 | 0.1 + 0.2 |
AC (10Hz to 1kHz) | 0.1 + 0.1 | 0.1 + 0.1 | 0.1 + 0.2 |
AC (10kHz) | 5 + 0.5 | 5 + 0.5 | 5 + 0.5 |
Current | |||
Crest Factor | CF ≤ 2 | ||
Temperature Coefficient | 0.05 x (Spec)/k | ||
Overload capacity | 10 % overload | ||
CMRR | 120 dB @ 50/60 Hz | ||
Shunt (current input) | |||
Measuring Range | 0.1 A, 1 A, 10 A | ||
Input Impedance | 0.025 Ω (Typical) | ||
Bandwidth | 10 A range: 500 kHz; 1 A range: 200 kHz; 0.1 A range: 100 kHz | ||
BNC (voltage input) | |||
Range | 0.1 V, 1 V, 10 V | ||
Input Impedance | 100k Ω/100pF (Typical) | ||
Bandwidth | 10 V range: 500 kHz; 1 V range: 200 kHz; 0.1 V range: 100 kHz |
Accuracy (% reading + % range) | ||||||
Range | 10 A | 1 A | 0.1 A | 10 V | 1 V | 0.1 V |
DC | 0.1 + 0.2 | 0.1 + 0.5 | 0.1+2 | 0.1+0.1 | 0.1+0.2 | 0.1+1 |
AC (10Hz to 1kHz) | 0.1+0.1 | 0.1+0.2 | 0.1+1 | 0.1+0.1 | 0.1+0.1 | 0.1+0.5 |
AC (10kHz) | 5+1 | 5+1 | 5+1 | 5+1 | 5+1 | 5+1 |
Motor Module (Torque and Speed) | ||||||
Voltage Range | ± 10 V dc, 10 % overload | |||||
Voltage Channels | 2 | |||||
Input Impedance | 1.1M Ω (Typical) | |||||
Accuracy at dc | 0.1 % range + 0.1 % reading | |||||
Pulse Channels | 3 | |||||
Pulse Logic High Threshold | 2 V (Typical) | |||||
Pulse Logic Low Threshold | 0.8 V (Typical) | |||||
Maximum Pulse Frequency | 100 kHz | |||||
Motor Module (Torque and Speed) | ||||||
Frequency Accuracy | 0.05 % range + 0.05 % reading | |||||
Harmonics | 100 (50Hz/60Hz) | |||||
Calculation method | FFT/Interpolation |
Equipment is available for rental.
Contact [email protected] for rental inquiry.