Fluke NORMA 6004 Portable Power Analyzer

$21,500.00

Category:

Description

File:Fluke Corporation logo.svg - Wikipedia

The Fluke Norma 6000 Series Portable Wideband Precision Power Analyzers give you more freedom than ever before to make high accuracy power measurements wherever you need to—whether in the lab, or in the field. Designed for portability the lightweight, battery powered Fluke 6000 Series eliminates the need to carry large, fragile, expensive analyzers into the field, allowing you to make measurements directly at the load in nearly any environment. By measuring directly at the load, you can discover how the equipment operates under real-world conditions, with real-world variables, not just at a test bench or in the lab.

Key features

  • Measure voltage, current, active power, reactive power, apparent power, power factor and harmonics with associated values
  • Get accurate, precise results with 0.1% measurement accuracy and a 500kHz bandwidth
  • Take precision power measurements almost anywhere – highly portable, battery powered analyzer weighing only 3.5kg with up to 10 hours of battery life.
Inputs Norma 6003 3 Voltage + 3 Current
Norma 6003+ 3 Voltage + 3 Current + 1 Motor
Norma 6004 4 Voltage + 4 Current
Norma 6004+ 4 Voltage + 4 Current + 1 Motor
Sample rate 200ks/s
Measurement update rate 100ms, 200ms, 500ms, 1s
Dimensions (H * W * L) 298mm x 215m x 96mm
Weight 3.5 kg (7.7 lbs)
Display 5.7 inch, TFT LCD, 640×480
Operating temperature -10 °C to +50 °C
Storage temperature -30 °C to +60 °C
Operating humidity Non-condensing (< 10 °C )
≤ 90 % RH (at 10 °C to 30 °C)
≤ 75 % RH (at 30 °C to 40 °C)
≤ 45 % RH (at 40 °C to 50 °C)
Operating altitude 2000m
Storage altitude 12000m
Ingress protection IP 50 (Terminals mated) according to IEC 60529:
Battery BP 291, 10.8V/5000mAh, 54Wh IEC 62133, UN38.3
Operating time: 10 Hours (on battery)
Safety IEC 61010-1: Pollution Degree 2
IEC 61010-2-030: CAT IV 600V, CAT III 1000 V
EMC IEC 61326-1: Industrial
IEC 61326-2-2
Warranty 1 Year
Communication Interface USB/RS485
Dual Analyzer Synchronization Mode Able to extend to 6, 7 or 8 channels (using multiple instruments)
PC Software Fluke Power Analyzer software
Storage Capacity 32GB
Data trend storage rate As per display rate
Main Function Meter, Scope, Harmonic, Phasor, Trend
Measuring Parameters RMS, DC Component, AC Component, Rectified Mean, Peak Value, Peak-Peak, Crest Factor, Form Factor, Fundamental Component, Fundamental Content, Harmonic Distortion, Harmonic Content, Harmonic Factor for voltages and currents, Active Power, Reactive Power, Apparent Power, Power Factor, Phase Shift, Efficiency, Impedance, Electric Energy, Charge/Discharge capacity (Ah), Frequency, Motor Speed, Torque, Mechanical Power, Mechanical Energy, Summation function
Electrical Specifications
Voltage
Range 10 V, 100 V, 1000 V
Crest Factor CF ≤ 2
Maximum Voltage 10 % overload
Input Impedance 2M Ω/10pF (Typical)
Temperature Coefficient 0.05 * (Spec)/k
Bandwidth 1000V range: 500kHz; 100V range: 200 kHz; 10V range:100 kHz
CMRR 120 dB @ 50/60 Hz
Accuracy (% reading + % range)
Range 1000 V 100 V 10 V
DC 0.1 + 0.1 0.1 + 0.1 0.1 + 0.2
AC (10Hz to 1kHz) 0.1 + 0.1 0.1 + 0.1 0.1 + 0.2
AC (10kHz) 5 + 0.5 5 + 0.5 5 + 0.5
Current
Crest Factor CF ≤ 2
Temperature Coefficient 0.05 x (Spec)/k
Overload capacity 10 % overload
CMRR 120 dB @ 50/60 Hz
Shunt (current input)
Measuring Range 0.1 A, 1 A, 10 A
Input Impedance 0.025 Ω (Typical)
Bandwidth 10 A range: 500 kHz; 1 A range: 200 kHz; 0.1 A range: 100 kHz
BNC (voltage input)
Range 0.1 V, 1 V, 10 V
Input Impedance 100k Ω/100pF (Typical)
Bandwidth 10 V range: 500 kHz; 1 V range: 200 kHz; 0.1 V range: 100 kHz
Accuracy (% reading + % range)
Range 10 A 1 A 0.1 A 10 V 1 V 0.1 V
DC 0.1 + 0.2 0.1 + 0.5 0.1+2 0.1+0.1 0.1+0.2 0.1+1
AC (10Hz to 1kHz) 0.1+0.1 0.1+0.2 0.1+1 0.1+0.1 0.1+0.1 0.1+0.5
AC (10kHz) 5+1 5+1 5+1 5+1 5+1 5+1
Motor Module (Torque and Speed)
Voltage Range ± 10 V dc, 10 % overload
Voltage Channels 2
Input Impedance 1.1M Ω (Typical)
Accuracy at dc 0.1 % range + 0.1 % reading
Pulse Channels 3
Pulse Logic High Threshold 2 V (Typical)
Pulse Logic Low Threshold 0.8 V (Typical)
Maximum Pulse Frequency 100 kHz
Motor Module (Torque and Speed)
Frequency Accuracy 0.05 % range + 0.05 % reading
Harmonics 100 (50Hz/60Hz)
Calculation method FFT/Interpolation

Equipment is available for rental. 

Contact [email protected] for rental inquiry.